Collector Certification (T-Z)
Collector |
Glazing |
Absorber |
Gross Area |
Thermal
Performance Intermediate Temperature Rating |
|||||
Manufacturer |
Model |
FSEC # | No. |
Type |
Material |
Coating |
Sq. Ft |
Btu/Day |
Btu/ft² |
Technosun Puerto Rico | 50GSSHP | 00053 | 1 | Evacuated glass tube | Copper tubes and aluminum retainers | Selective | 17.66 | Thermosiphon System Net Energy Delivered: 9,900 Btu Heat Loss Coefficient: 2.5 Btu/hr°F |
|
Thermal Conversion Technology | PT-20-CN | 00164C | 2 | Glass and thin film plastic | Copper tubing | Moderately selective | 12.56 | ICS System Net Energy Delivered: 11,600 Btu Heat Loss Coefficient: 7.5 Btu/hr°F |
|
Thermal Conversion Technology | PT-30-CN | 95003 | 2 | Glass and thin film plastic | Copper tubing | Moderately selective | 24.02 | ICS System Net Energy Delivered: 22,100 Btu Heat Loss Coefficient: 13.2 Btu/hr°F |
|
Thermal Conversion Technology | PT-35-CN | 95012C | 2 | Glass and thin film plastic | Copper tubing | Moderately selective | 24.02 | ICS System Net Energy Delivered: 22,400 Btu Heat Loss Coefficient: 13.2 Btu/hr°F |
|
Thermal Conversion Technology | PT-40-CN | 95016C | 2 | Glass and thin film plastic | Copper tubing | Moderately selective | 32.10 | ICS System Net Energy Delivered: 28,400 Btu Heat Loss Coefficient: 17.1 Btu/hr°F |
|
Thermal Conversion Technology | PT-50-CN | 95013C | 2 | Glass and thin film plastic | Copper tubing | Moderately selective | 32.12 | ICS System Net Energy Delivered: 28,700 Btu Heat Loss Coefficient: 17.1 Btu/hr°F |
|
Thermo Dynamics Ltd. | G32 | 92015N | 1 | Glass | Copper tubes and aluminum fins | Selective | 32.04 | 27700 | 865 |
Thermomax Industries Ltd. | Solamax AST 20 | 00109 | 1 | Evacuated glass tube | Copper tubes and fins | Selective | 30.67 | 22300 | 727 |
Thermomax | TMA600 | 97005 | 1 | Evacuated glass tube | Copper fins welded to heat pipe | Selective | 49.31 | 37300 | 757 |
Thermomax USA Ltd. | THS 200 | 85089W | 1 | Glass | Copper tubes and fins | Selective | 22.62 | 17800 | 785 |
Thermomax USA Ltd. | TST 300 | 92017 | 1 | Evacuated glass tube | Copper fin welded to heat pipe | Selective | 22.68 | 14400 | 634 |
Thermosol de Puerto Rico Inc. | T.S. 001 | 86005 | 1 | Glass | Copper tubes and aluminum fins | Nonselective | 20.29 | 12500 | 615 |
Thermtube | TH 1.5/ 12 CN |
00071 | 1 | Evacuated glass tube | Copper tubes and aluminum fins | Selective | 13.28 | 9,600 | 726 |
United Marketing Associates, Inc. | Solar Max-40 | 93003 | 1 | FRP | UV stabilized polypropylene | None | 39.49 | 18800 | 475 (See Note 1) |
Universal Solar Products, Inc. | USP-519 | 97011 | 1 | Glass | Copper tubes and fins | Selective | 18.22 | 14400 | 788 |
X-Therm Solar | XTS V-8 | 00070 | 1 | Evacuated glass tube | Copper tubes and aluminum fins | Selective | 21.23 | 15200 | 716 |
ZH Caribbean Enterprises, Inc. | Solar King 101 | 00131C | 1 | Evacuated glass tube | Copper tubes and aluminum fins | Selective | 21.50 | 15900 | 739 |
ZH Caribbean Enterprises, Inc. | Solar King 102 | 00132C | 1 | Evacuated glass tube | Copper tubes and aluminum fins | Selective | 42.99 | 31800 | 739 |
ZH Caribbean Enterprises, Inc. | Solar King SK-40 |
00137N | 1 | Glass | Copper tubes and fins | Selective | 39.79 | 34400 | 866 |
Note 1: This collector has no integral back surface material. It was treated and rated mounted on a plywood base covered with white roll roofing. This collector is only certified for flush mounting to a smooth surface. |