Collector Certification (B-R)

Collector

Glazing

Absorber
Gross Area
Thermal Performance
Intermediate Temperature Rating
Manufacturer Model FSEC # No. Type Material Coating Sq. Ft Btu/Day Btu/ft²
Beijing Sunda Solar Energy Technology Co. Ltd. SEIDO1-8 00100 1 Evacuated glass tube Copper tubes and aluminum fins Selective 21.50 15900 739
Beijing Sunda Solar Energy Technology Co. Ltd. SEIDO1-16 00101C 1 Evacuated glass tube Copper tubes and aluminum fins Selective 42.99 31800 739
Beijing Sunda Solar Energy Technology Co. Ltd. SEIDO
5-8 AS/AB
00226N 1 Evacuated glass tube   Copper tubes and aluminum fins Selective 21.83 14400 660
Beijing Sunda Solar Energy Technology Co. Ltd. SEIDO
5-16 AS/AB
00227N 1 Evacuated glass tube Copper tubes and aluminum fins Selective 44.10 28700 651
Chromagen SSH 170/2D 97021 1 Glass Copper tubes and fins Selective 30.29  Thermosiphon System
Net Energy Delivered:
25,300 Btu
Heat Loss Coefficient:
2.9 Btu/hr°F   
Dawn Solar Systems 2000 99043 0 None PEX tubing,
below metal roof
Nonselective 46.42 See Note 1
Dawn Solar Systems DS-2004 00124 0 None PEX tubing,
below metal roof
Nonselective 100.13 See Note 2
Dawn Solar Systems 3004-CT 00150 0 None PEX tubing,
below concrete tile roof
Nonselective 101.84 See Note 3
Dawn Solar Systems DS-2004-RB 00167 0 None PEX tubing,
below metal roof with foil faced radiant barrier
Nonselective 100.13 See Note 6
DeLuge Machino-
craft
MSC101
99001 1 Glass Copper tubes and fins Selective 24.82 17700 715
Duke Solar Energy, LLC CPC 2000 00042 1 Glass Copper tubes with reflector Selective 24.17 19800 821
EnerWorks, Inc. EW-SDHW-B6-02-TL 00105N 1 Glass Copper tubes and aluminum sheet Selective 31.12 24500 786
FAFCO Inc. Revolution
908R
98003C 0 None UV stabilized plastic polymer None 31.76 18300 576
FAFCO Inc. Revolution
910R
98004C 0 None UV stabilized plastic polymer None 39.70 22900 576
FAFCO Inc. Revolution
912R
96023 0 None UV stabilized plastic polymer None 47.45 27300 576
FAFCO Inc. SunSaver 918 95001C 0 None UV stabilized plastic polymer None 31.60 14300 452
FAFCO Inc. SunSaver 920 95002C 0 None UV stabilized plastic polymer None 39.50 17900 452
FAFCO Inc. SunSaver 922 95006C 0 None UV stabilized plastic polymer None 47.79 21600 452
FAFCO Inc. 960 97003C 0 None UV stabilized plastic polymer None 80.00 36200 452
Freedom Solar Freedom 10 00218K 1 Glass Copper tubes and aluminum fins Selective 13.54 See Note 4
Gezelman Solar Super 4x8 85046C 1 Glass Copper tubes and fins Selective 33.05 24100 730
Gezelman Solar Super 4x10 83178 1 Glass Copper tubes and fins Selective 41.08 30300 737
Heliocol U.S.A. Inc. Chromagen
CA110
00093 1 Glass Copper tubes and fins Selective 25.48 19100 750
Heliocol U.S.A. Inc. Alpha 32 00229C 1 Glass Copper tubes and fins Selective 31.98 24200 756
Heliocol U.S.A. Inc. Alpha 40 00230C 1 Glass Copper tubes and fins Selective 40.06 30100 752
Heliodyne, Inc. Gobi 3366 00003D 1 Glass Copper tubes and fins Selective 26.79 24300 906
Heliodyne, Inc. Gobi 308 95005D 1 Glass Copper tubes and fins Selective 24.09 21600 897
Heliodyne, Inc. Gobi 408 94013D 1 Glass Copper tubes and fins Selective 32.22 29400 912
Heliodyne, Inc. Gobi 410 94014D 1 Glass Copper tubes and fins Selective 40.15 36800 916
Mid-Carolina Solar MCS321 85061 1 Glass Copper tubes and aluminum fins Selective 32.16 23600 735
Mid-Carolina Solar MCS401 85096C 1 Glass Copper tubes and aluminum fins Selective 40.29 29600 734
Nippon Electric Glass America PK10
Pumped system
92040 1 Evacuated glass tube Copper tank Selective 16.19 100 6
Nippon Electric Glass America PK-20
(Consists of two 17.96 sq
ft collectors)
92004 1 Evacuated glass tube Copper tank Selective 35.91
See Note 5
Nippon Electric Glass America PK-30
(Consists of three 17.96 sq ft collectors)
92014N 1 Evacuated glass tube Copper tank Selective 53.87

ICS System
Net Energy Delivered:
28,000 Btu
Heat Loss Coefficient:
23.3 Btu/hr°F

Nippon Electric Glass America PK10 Sunfamily 92030 1 Evacuated glass tube Copper tank Selective 16.19 12900 796
Nippon Electric Glass America Suntube DP6-2800 92010N 1 Evacuated glass tube Copper tubes and steel fins Selective 29.75 21000 705
Productos de Sol, S.A. CSP-20-B 81036 1 Glass Copper tubes and aluminum fins Nonselective 20.71 14900 719
Productos de Sol, S.A. CSP-20-B Selective 84002 1 Glass Copper tubes and aluminum fins Selective 20.54 16500 804
R&R Services EPI-308SS (3x7) 98019 1 Glass Selective Copper tubes and fins Selective 20.47 15900 778
R&R Services EPI308AL 3'x8' 92035D 1 Glass Copper tubes and fins Nonselective 24.05 18700 777
R&R Services EPI308AL 4'x8' 92036D 1 Glass Copper tubes and fins Nonselective 32.20 25500 792
Rheem Water Heaters RS21-BC 00223C 1 Glass Steel sheets with integral tubes Selective 21.34 19100 895
Rheem Water Heaters RS21-BP 00224C 1 Glass Steel sheets with integral tubes Nonselective 21.34 17200 804
Rheem Water Heaters RS21-SC 00225C 1 Glass Copper tubes and sheet Selective 21.35 19300 903
Rope-A-Ray Solar Systems *DAL-02 83056 1 Glass Copper tubing Nonselective 35.33 23900 677
Rope-A-Ray Solar Systems RRH-W896
SG/ DAL-02
83151 1 Glass Copper tubes and aluminum fins Nonselective 34.66 20900 602
Note 1: This collector is structurally integrated into a metal roof system. Its low temperature rating is 4800 Btu for the test area of 46.4 square feet or 104 Btu per square feet.
Note 2: This collector is structurally integrated into a metal roof system. Its low temperature rating is 15,100 Btu for the test area of 100.1 square feet or 151 Btu per square feet.
Note 3: This collector is structurally integrated into a concrete tile roof system. Its low temperature rating is 7,400 Btu for the test area of 101.84 square feet or 73 Btu per square feet.
Note 4: This collector is conditionally certified. The purpose of the conditional certification tests is to verify initial quality of construction only. The resulting conditional certification is not a guarantee of long term durability. Full scale testing and evaluation are to be completed within one year from the date of conditional certification. Conditional certification issued March 2006.
Note 5: Integral storage system tested to FSEC ICS test procedures. Please contact the Testing & Operations Division to obtain the unit's summary information sheet.
Note 6: This collector is structurally integrated into a metal roof system. The roof system also includes a foil faced radiant barrier. Its low temperature rating is 14,400 Btu for the test area of 100.1 square feet or 144 Btu per square feet.
*The flow rate through a solar collector affects its performance, but may or may not affect the performance of the system in which it is installed. Some of the collectors listed here have been tested at flow rates other than those specified by testing standards. These collector models are identified with an asterisk (*) immediately preceding the model number.