Collector Certification (B-R)
Collector |
Glazing |
Absorber |
Gross Area |
Thermal Performance Intermediate Temperature Rating |
|||||
Manufacturer | Model | FSEC # | No. | Type | Material | Coating | Sq. Ft | Btu/Day | Btu/ft² |
Beijing Sunda Solar Energy Technology Co. Ltd. | SEIDO1-8 | 00100 | 1 | Evacuated glass tube | Copper tubes and aluminum fins | Selective | 21.50 | 15900 | 739 |
Beijing Sunda Solar Energy Technology Co. Ltd. | SEIDO1-16 | 00101C | 1 | Evacuated glass tube | Copper tubes and aluminum fins | Selective | 42.99 | 31800 | 739 |
Beijing Sunda Solar Energy Technology Co. Ltd. | SEIDO 5-8 AS/AB |
00226N | 1 | Evacuated glass tube | Copper tubes and aluminum fins | Selective | 21.83 | 14400 | 660 |
Beijing Sunda Solar Energy Technology Co. Ltd. | SEIDO 5-16 AS/AB |
00227N | 1 | Evacuated glass tube | Copper tubes and aluminum fins | Selective | 44.10 | 28700 | 651 |
Chromagen | SSH 170/2D | 97021 | 1 | Glass | Copper tubes and fins | Selective | 30.29 | Thermosiphon System Net Energy Delivered: 25,300 Btu Heat Loss Coefficient: 2.9 Btu/hr°F |
|
Dawn Solar Systems | 2000 | 99043 | 0 | None | PEX tubing, below metal roof |
Nonselective | 46.42 | See Note 1 | |
Dawn Solar Systems | DS-2004 | 00124 | 0 | None | PEX tubing, below metal roof |
Nonselective | 100.13 | See Note 2 | |
Dawn Solar Systems | 3004-CT | 00150 | 0 | None | PEX tubing, below concrete tile roof |
Nonselective | 101.84 | See Note 3 | |
Dawn Solar Systems | DS-2004-RB | 00167 | 0 | None | PEX tubing, below metal roof with foil faced radiant barrier |
Nonselective | 100.13 | See Note 6 | |
DeLuge | Machino- craft MSC101 |
99001 | 1 | Glass | Copper tubes and fins | Selective | 24.82 | 17700 | 715 |
Duke Solar Energy, LLC | CPC 2000 | 00042 | 1 | Glass | Copper tubes with reflector | Selective | 24.17 | 19800 | 821 |
EnerWorks, Inc. | EW-SDHW-B6-02-TL | 00105N | 1 | Glass | Copper tubes and aluminum sheet | Selective | 31.12 | 24500 | 786 |
FAFCO Inc. | Revolution 908R |
98003C | 0 | None | UV stabilized plastic polymer | None | 31.76 | 18300 | 576 |
FAFCO Inc. | Revolution 910R |
98004C | 0 | None | UV stabilized plastic polymer | None | 39.70 | 22900 | 576 |
FAFCO Inc. | Revolution 912R |
96023 | 0 | None | UV stabilized plastic polymer | None | 47.45 | 27300 | 576 |
FAFCO Inc. | SunSaver 918 | 95001C | 0 | None | UV stabilized plastic polymer | None | 31.60 | 14300 | 452 |
FAFCO Inc. | SunSaver 920 | 95002C | 0 | None | UV stabilized plastic polymer | None | 39.50 | 17900 | 452 |
FAFCO Inc. | SunSaver 922 | 95006C | 0 | None | UV stabilized plastic polymer | None | 47.79 | 21600 | 452 |
FAFCO Inc. | 960 | 97003C | 0 | None | UV stabilized plastic polymer | None | 80.00 | 36200 | 452 |
Freedom Solar | Freedom 10 | 00218K | 1 | Glass | Copper tubes and aluminum fins | Selective | 13.54 | See Note 4 | |
Gezelman Solar | Super 4x8 | 85046C | 1 | Glass | Copper tubes and fins | Selective | 33.05 | 24100 | 730 |
Gezelman Solar | Super 4x10 | 83178 | 1 | Glass | Copper tubes and fins | Selective | 41.08 | 30300 | 737 |
Heliocol U.S.A. Inc. | Chromagen CA110 |
00093 | 1 | Glass | Copper tubes and fins | Selective | 25.48 | 19100 | 750 |
Heliocol U.S.A. Inc. | Alpha 32 | 00229C | 1 | Glass | Copper tubes and fins | Selective | 31.98 | 24200 | 756 |
Heliocol U.S.A. Inc. | Alpha 40 | 00230C | 1 | Glass | Copper tubes and fins | Selective | 40.06 | 30100 | 752 |
Heliodyne, Inc. | Gobi 3366 | 00003D | 1 | Glass | Copper tubes and fins | Selective | 26.79 | 24300 | 906 |
Heliodyne, Inc. | Gobi 308 | 95005D | 1 | Glass | Copper tubes and fins | Selective | 24.09 | 21600 | 897 |
Heliodyne, Inc. | Gobi 408 | 94013D | 1 | Glass | Copper tubes and fins | Selective | 32.22 | 29400 | 912 |
Heliodyne, Inc. | Gobi 410 | 94014D | 1 | Glass | Copper tubes and fins | Selective | 40.15 | 36800 | 916 |
Mid-Carolina Solar | MCS321 | 85061 | 1 | Glass | Copper tubes and aluminum fins | Selective | 32.16 | 23600 | 735 |
Mid-Carolina Solar | MCS401 | 85096C | 1 | Glass | Copper tubes and aluminum fins | Selective | 40.29 | 29600 | 734 |
Nippon Electric Glass America | PK10 Pumped system |
92040 | 1 | Evacuated glass tube | Copper tank | Selective | 16.19 | 100 | 6 |
Nippon Electric Glass America | PK-20 (Consists of two 17.96 sq ft collectors) |
92004 | 1 | Evacuated glass tube | Copper tank | Selective | 35.91 | See Note 5 |
|
Nippon Electric Glass America | PK-30 (Consists of three 17.96 sq ft collectors) |
92014N | 1 | Evacuated glass tube | Copper tank | Selective | 53.87 | ICS System |
|
Nippon Electric Glass America | PK10 Sunfamily | 92030 | 1 | Evacuated glass tube | Copper tank | Selective | 16.19 | 12900 | 796 |
Nippon Electric Glass America | Suntube DP6-2800 | 92010N | 1 | Evacuated glass tube | Copper tubes and steel fins | Selective | 29.75 | 21000 | 705 |
Productos de Sol, S.A. | CSP-20-B | 81036 | 1 | Glass | Copper tubes and aluminum fins | Nonselective | 20.71 | 14900 | 719 |
Productos de Sol, S.A. | CSP-20-B Selective | 84002 | 1 | Glass | Copper tubes and aluminum fins | Selective | 20.54 | 16500 | 804 |
R&R Services | EPI-308SS (3x7) | 98019 | 1 | Glass Selective | Copper tubes and fins | Selective | 20.47 | 15900 | 778 |
R&R Services | EPI308AL 3'x8' | 92035D | 1 | Glass | Copper tubes and fins | Nonselective | 24.05 | 18700 | 777 |
R&R Services | EPI308AL 4'x8' | 92036D | 1 | Glass | Copper tubes and fins | Nonselective | 32.20 | 25500 | 792 |
Rheem Water Heaters | RS21-BC | 00223C | 1 | Glass | Steel sheets with integral tubes | Selective | 21.34 | 19100 | 895 |
Rheem Water Heaters | RS21-BP | 00224C | 1 | Glass | Steel sheets with integral tubes | Nonselective | 21.34 | 17200 | 804 |
Rheem Water Heaters | RS21-SC | 00225C | 1 | Glass | Copper tubes and sheet | Selective | 21.35 | 19300 | 903 |
Rope-A-Ray Solar Systems | *DAL-02 | 83056 | 1 | Glass | Copper tubing | Nonselective | 35.33 | 23900 | 677 |
Rope-A-Ray Solar Systems | RRH-W896 SG/ DAL-02 |
83151 | 1 | Glass | Copper tubes and aluminum fins | Nonselective | 34.66 | 20900 | 602 |
Note 1: This collector is structurally integrated into a metal roof system. Its low temperature rating is 4800 Btu for the test area of 46.4 square feet or 104 Btu per square feet. | |||||||||
Note 2: This collector is structurally integrated into a metal roof system. Its low temperature rating is 15,100 Btu for the test area of 100.1 square feet or 151 Btu per square feet. | |||||||||
Note 3: This collector is structurally integrated into a concrete tile roof system. Its low temperature rating is 7,400 Btu for the test area of 101.84 square feet or 73 Btu per square feet. | |||||||||
Note 4: This collector is conditionally certified. The purpose of the conditional certification tests is to verify initial quality of construction only. The resulting conditional certification is not a guarantee of long term durability. Full scale testing and evaluation are to be completed within one year from the date of conditional certification. Conditional certification issued March 2006. | |||||||||
Note 5: Integral storage system tested to FSEC ICS test procedures. Please contact the Testing & Operations Division to obtain the unit's summary information sheet. | |||||||||
Note 6: This collector is structurally integrated into a metal roof system. The roof system also includes a foil faced radiant barrier. Its low temperature rating is 14,400 Btu for the test area of 100.1 square feet or 144 Btu per square feet. | |||||||||
*The flow rate through a solar collector affects its performance, but may or may not affect the performance of the system in which it is installed. Some of the collectors listed here have been tested at flow rates other than those specified by testing standards. These collector models are identified with an asterisk (*) immediately preceding the model number. |