Implementing
Systems Engineering in HUD Code Manufactured Housing Factories
Leads – Dave Chasar, Neil Moyer, David Beal (FSEC), Mike Lubliner
(WSU) and
Tom Hewes (Oregon DOE).
Lessons
Learned:
BAIHP has found that using building
science and the systems engineering approach to help
industry partners solve difficult problems develops
a strong working relationship and increases the likelihood
of the partner incorporating concepts central to
achieving Building America goals such as sealed and
tested ducts, properly sized air conditioning, and
moisture management. |
At the request of HUD code home manufacturers, BAIHP researchers
have conducted reviews and consulted on ways to make the homes’ systems
work better together with six HUD Code home manufacturers. BAIHP consultation,
recommendations, and training led to sweeping changes at four manufacturers’ factories
that resulted in more than 106,000 energy-improved homes built in
the past five and a half years. Changes included:
- Switching from tape to mastic duct sealing
- Improved duct cutting, mating, and strapping practices
- Testing of duct systems produced in the factory
- Addition of through-wall or jump duct return air pathways to bedrooms.
|
Duct testing rig at Palm Harbor
Homes, Plant City factory. |
BAIHP worked with manufacturers to test the duct systems (and other
performance indicators) in 101 houses representing 190 individually
manufactured “sections.” The data was collected during
39 factory visits to 24 factories of six manufacturers between 1996
and 2003, and it showed robust correlation between duct leakage to
the outside in completed houses (which can only be measured after
the house is fully assembled) and total duct leakage (which can be
measured in each section while it is on the production line) as well
as evidence that substantially air-tight duct construction with mastic
could be cost-effectively achieved in the HUD Code home manufacturing
environment.
Based on this data, the National Fire Protection Association’s
(NFPA) approved a new standard on duct tightness, as well as a refined
duct-testing protocol. Typically, standard NFPA-501 is ultimately incorporated
into the HUD Code, which governs the construction of more than 250,000
HUD code homes each year.
BAIHP work with HUD Code manufacturers also resulted in indoor air
quality studies facilitated with LBNL and in many factories becoming
ENERGY STAR-certified.
BAIHP Factory Builder Partners include:
- Cavalier Homes
- Clayton Homes
- Fleetwood Homes
- Palm Harbor Homes
- Southern Energy Homes
- Redman Homes (defunct)
Resources:
The complete research paper can be viewed at:
"ENERGY STAR Manufactured Homes: The Plant Certification Process"